- RADIO SHACK 17-3001/1075, CT100/101
-
- NOTES: This is a single NAM unit.
- The ESN prefix is 165 decimal & A5 hex.
- Radio Shack: 817-390-3234
-
-
- NAM PROGRAMING:
-
- 1. Turn power on.
-
- 2. Enter * 1 7 * 3 0 0 1 * L L L L *, where LLLL is the lock code, the
- factory default is 1234. If the lock code is not known and can't be
- guessed the phone can not be programed without a Nokia service handset.
-
- 3. Press SEL to store data and scroll between parameter names and values.
-
- 4. Press CLR to correct an entry.
-
- 5. Press END to abort programing.
-
- 6. At any time press SEL END to exit and complete programing, the phone
- will also automatically exit if you scroll through all parameters.
-
-
- PROGRAMING DATA
-
- STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION
-
- 01 00000 - 32767 HO-Id SYSTEM ID
- 02 0 OR 1 ACCESS ACCESS METOD (MIN MARK)
- 03 0 OR 1 LOCAL LOCAL USE MARK
- 04 10 DIGITS Phone N MIN (AREA CODE & TEL#)
- 05 08 ONLY CLASS STATION CLASS MARK
- 06 333 OR 334 PAGE ch INITIAL PAGING CHANNEL
- 07 2 DIGITS O-LOAd ACCESS OVERLOAD CLASS
- 08 2 DIGITS GrouP GROUP ID (10 IN USA)
- 09 4 DIGITS Loc CodE LOCK CODE
-
- NOTE: It is suggested that the lock code be either left at 1234, or
- the last four digits of the phone number.
-
- LOCK: SEL LOCK, UNLOCK: FOUR DIGIT LOCK CODE
-
- SYSTEM SELECT: SEL 1, THEN 1 UNTIL DESIRED OPTION IS DISPLAYED
-
- A = A ONLY
- B = B ONLY
- S = PREF/NON PREF